Home |  Products & Services | Technical Support | About us    
 
  Back
         
  Membrane for Lateral Flow Tests
   


mdi produces highly consistent and optimized Nitrocellulose (NC) membranes for lateral flow tests. A wide variety of membranes are available in roll form as standard products to meet various needs.

Cellulose Nitrate Membrane Disc Filter
   
  Types Available
 
Membrane Type CNPF, CNPC and CNPH-N are directly cast on a transparent polyester backing to improve the handling strength. Standard polyester film is 100µm thick, although other thickness can be available on order.
 
Type
Feature
Lower protein binding
Higher protein binding
Highest protein binding. A high strength, scratch resistant membrane
 
  Technical Data

The wicking rate primarily determines the reaction kinetics and is an important characteristic of NC membrane for lateral flow tests. mdi membranes are designated by pore size/wicking rate and have reproducible and defined wicking rates. The wicking rate of blocked membranes will, however depend on the blocking protocol.

Technical data for various membranes.

  CNPF
 
Type
CNPF
Nominal Pore Size (µm)
5
8
10
12
Membrane thickness (µm)
100
100
100
100
4cm Wicking Time (sec) (blocked)
185
155
100
95
4cm Wicking Time (sec) (unblocked)
220
190
130
120
 
  CNPC
 
Type
CNPC
Rating
10
12
15
Membrane thickness (µm)
105
105
105
4cm Wicking Time (sec) (blocked)
120
95
80
4cm Wicking Time (sec) (unblocked)
140
120
100
 
  CNPH-N
 
Type
CNPH-N
Nominal Pore Size (µm)
90
150
200
Membrane thickness (µm)
110
110
110
4cm Wicking Time (sec) (blocked)
75
125
165
4cm Wicking Time (sec) (unblocked)
90
150
200
 
  How to Select Membrane
 
Selection of membrane depends on the assay. Highest sensitivity is obtained with smaller pore size (slower wicking rate). For high affinity Ag/Ab reaction, use of bigger pore size (faster wicking rates) can result in faster test with adequate sensitivity.
Pore Size
(Wicking time)
5,8µm
(180-220 sec)
10.12µm
(110-150 sec)
15µm
(90 sec)
Characteristics of the test system
- Highest sensitivity
- Slower migration
- Longer test time
- Sharp line
- Medium sensitivity
- Medium migration rate
- Medium test time
- Sharp line
- Lower sensitivity
- Fast migration
- Quick test
- Relatively diffused   signal line
Typical applications
- Hbs Ag serum
- Urine Ab tests
- Environmental and
  Agricultural analytes
- Milk testing

- hCG
- Heat disease markers
- Cancer markers
- Drugs of Abuse
- Infectious disease tests
- Whole blood tests
- Environmental and   agriculture   analytes
- hCG
- Malaria
- Whole blood tests

 

 

  Storage
 

mdi recommends storage of membrane rolls at 15 °C to 20 °C for longer shelf life. The membrane rolls should be kept away from heat radiators. membrane is inflammable when subjected to direct heat.

 
  What is Special About mdi Membranes
 

Consistency and stability of NC membranes has long been an issue for manufacturers of membrane based assays. By an optimised surface chemistry and unique processing techniques mdi has resolved these issues. mdi membranes are highly consistent and exhibit extremely low variation. Typical coefficient of variation(CV) for thickness of membrane is 3.5% whereas that for the wicking rate is 4%.


Fig. Typical stability data of mdi membranes
 

As seen in the figure the mdi membranes with detergents are extremely stable.

 

Ordering Information
 
       
The membrane can be ordered as below:      
Information
Membrane Type
with rating
Width of roll
(in mm)***
Length of roll
(in meters) ****
Quantity
Example 1
CNPF-10μ*
25mm
50M or 100M
20,000
Example 2
CNPF-10μ*
20mm
50M or 100M
15,000
Example 3
90CNPH-N*
25mm
50M or 100M
18,000
         
           
  To order please specify:
   
  * The CNPC and CNPF rating is suffixed to membrane type.
** The CNPH-N rating is prefixed to the Membrane type -CNPH-N.
*** The widths are as per the customer requirement. 25mm is most widely used membrane size.
**** The membranes in reels form are supplied on standard 3 inches plastic core.

 
     

  
 
 
 
 
 
       
       
 
 
 
 
 
 
 
 
 
     
     
     
     
   
   
   
   
   

All Rights Reserved © Advanced Microdevices Pvt. Ltd 2009