Nylon 66 Membrane Disc Filters Type - HNN
|
|
|
| |
|
 |
|
mdi HNN membrane disc filters are, hydrophilic, non-media migrating, biologically inert, plain white absolute membrane filters useful for aqueous as well as organic
solvent filtration. |
| |
|
| |
|
|
|
| |
|
|
|
| |
- Very low extractables
- Wide chemical compatibility
- HPLC certified: assures that the filter will not add artifacts to the sample
|
| |
|
|
| |
| Pore size |
0.2µm |
0.45µm |
0.8µm |
1.2µm |
| Diameter |
13mm, 25mm, 47mm |
Water flow Rates (ml/min/cm2) at ⌂P=10psi, 20°C |
14 |
37 |
120 |
180 |
| Retention Efficiency |
0.2µm:LRV>7 for Br.diminuta |
|
Maximum Operating Temperature: 80°C continuous
Maximum Operating Pressure: 5Kg/cm²
Biosafety: Passes the Biological tests for class VI plastics as described in USP
Extractables with water: Within limits specified in USP
Oxidizable Matter: Passes test as per USP |
|
| |
Why do you need to filter your samples and solvents?
|
|
|
| |
Filtration of samples and solvents not only increases the accuracy and reliability of the
results but also prevents instrument downtime and extends the time between
maintenance or repairs.
Accuracy and reliability
1. Eliminates background peaks
2. Assures correct and reproducible volumes are injected into the system
3. Eliminates dissolved gases in the mobile phase which cause“noise”in the detector
Instrument downtime
1. Prevents plugging of critical valves and small ID tubing in the analytical
instrument
2. Extends the life of the analytical column |
|
|
| |
Water Flow Rates (ml/min/cm² @ ∆P=10psi at 27 °C) |
Top |
|
| |
Pore size |
HNN |
0.2µm |
12.0 |
0.45µm |
32.0 |
|
| |
|
|
| |
|
Size |
Dia |
Code |
13mm |
03 |
25mm |
06 |
47mm |
09 |
|
Pore Size |
Pore Size |
Code |
0.2µm |
01 |
0.45µm |
02 |
|
|
|
Sterile/ Non
Sterile |
|
Code |
Non Sterile |
1 |
|
Pack Size |
Pack Size |
Code |
100 |
04 |
|
| |
|
|
|
| |
|
| |
|
|
|
|
|
| |
|
|